Customer Feedback Vol. 3 Refrigerated Warehouse "Teratec Method"

Introducing a conversation with Ichiyou regarding the floor sinking correction work using the Teratec method.

In September 2017, we spoke with Mr. Toshio Baba, Vice President of Oriichi Co., Ltd., who conducted floor sinking correction work for a refrigerated and frozen warehouse using the "Terra Tech Method." The company was founded in 1953 in Imaichi City, Tochigi Prefecture, with the aim of manufacturing and selling wooden folding boxes and paper containers. Since then, it has expanded its business to include cardboard manufacturing, corrugated production, a weight bag system division, a packaging division, a packaging materials and equipment division, and the refrigerated warehouse and frozen transportation division that we worked on this time. This document includes information about the situation before construction, the reasons for choosing our company, and details about the construction work. [Contents] ■ Situation before construction and the trigger for the inquiry ■ Reasons for choosing our company ■ I was surprised by the beauty of the finish ■ Space efficiency is important for refrigerated warehouses ■ Details about our construction work * You can download materials that include customer feedback. * For more details, please feel free to contact us. Toll-free number: 0120-873-835

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] Bag Manufacturing Factory in Miyagi Prefecture

We will introduce a case of a bag manufacturing factory that sank due to ground subsidence and the impact of an earthquake!

We would like to introduce a case study of floor sinking correction work and subfloor void filling work carried out at a bag manufacturing factory located in Miyagi Prefecture. The neatly arranged bag-making machines were tilted due to floor sinking, which hindered production. As a temporary measure, legs (for height adjustment) were installed under the machines to level them, allowing work to continue. Consequently, we received a request for correction from the company, as we can quickly make adjustments without removing the machines, and we proceeded with the work. In addition to the floor sinking, voids were also observed under the floor, so we carried out the filling work as well. [Case Study] ■ Construction Area: Approximately 730m² ■ Maximum Sinking Amount: Approximately 110mm ■ Construction Period: 3 days *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Other contract services
  • Exhibition planning/construction

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] T Printing Company Factory in Miyagi Prefecture

We would like to introduce several examples of factories in the industrial zone of Miyagi Prefecture that have been modified using our construction method!

We would like to introduce a case of floor vibration suppression work carried out at the T Printing Company factory located in Miyagi Prefecture. In a factory where a machine weighing approximately 26 tons is placed, the floor began to vibrate after the earthquake. To confirm the situation before the installation of the machine, core drilling was performed at several locations. As a result, it was confirmed that there was a gap of up to approximately 180mm beneath the concrete. By carrying out gap filling work, we were able to restore the original performance of the concrete floor and suppress the floor vibrations. Additionally, we also conducted floor subsidence correction work at a factory of T Industry located in Miyagi Prefecture. 【Case Study】 <Floor Vibration Suppression Work at T Printing Company Factory in Miyagi Prefecture> ■ Construction: (Phase 1) July 2011, (Phase 2) October 2011 ■ Maximum Gap Size: Approximately 180mm ■ Total Construction Area: Approximately 160m2 ■ Actual Working Days: 1.5 days *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Other contract services
  • Exhibition planning/construction

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Correction Work for Floor Subsidence in Store - Continuous Night Work Without Stopping Business

Maximum subsidence of 144mm, construction area of approximately 2,300m2! Introduction of a case where corrections were made over 11 consecutive nights of construction.

Due to the impact of the Great East Japan Earthquake, the floor inside the store has significantly sunk. As a result of the floor sinking, gaps were observed between the floor and walls, as well as between the walls and ceiling. Therefore, our company carried out repair work. The "Upcon Method," which can be implemented at night during the business suspension, was adopted for the repairs. Additionally, voids were observed under the floor, so filling work was also conducted. 【Construction Overview】 ■ Construction Area: Approximately 2,300m2 ■ Maximum Settlement: 144mm ■ Construction completed in 2012, with repairs made over 11 consecutive nights. *For more details, please refer to the PDF document or feel free to contact us.

  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Parts Manufacturer Factory: Floor Slab Settlement Correction Work

A case where the earthen floor, which had subsided and developed gaps due to the earthquake, was repaired in a short construction period without demolishing the existing floor!

We would like to introduce a case of "floor slab settlement correction work" and "void filling work under the floor slab" conducted at a parts manufacturer factory in Fukushima Prefecture. There were various areas within the factory experiencing settlement and deflection, resulting in a wavy floor slab and the formation of voids in addition to the settlement. After the work was completed, the floor slab in the factory was corrected to nearly level, and to suppress vibrations caused by forklift passage, focused injection filling was performed in the aisle areas to mitigate vibrations. [Case Summary] ■ Construction Area: Approximately 1,470 m² ■ Maximum Settlement: 40 mm ■ Maximum Void: 60 mm ■ Area: Parts manufacturer located in Fukushima Prefecture ■ Construction Period: 11 days *For more details, please refer to the PDF document or feel free to contact us.

  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Food Processing Plant: Earthquake Recovery Floor Slab Settlement Correction Work

Settlement of the earthen floor caused by the earthquake! Correcting the settled floor before the factory renovation work in a short period.

We would like to introduce a case of "floor sinking correction work (earthquake recovery work)" carried out at a food processing factory in Iwate Prefecture. Due to the impact of the Great East Japan Earthquake, extensive renovations were necessary, and to achieve a swift recovery, the Upcon method, which allows for quick corrections, was adopted. The construction area was approximately 1,135 m², with a maximum gap of 221 mm. The construction period was six days, utilizing two construction plant vehicles. 【Case Overview】 ■ Construction Area: Approximately 1,135 m² ■ Maximum Gap: 221 mm ■ Area: Iwate Prefecture ■ Construction Period: 6 days (※ Supported by two construction plant vehicles) *For more details, please refer to the PDF document or feel free to contact us.

  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] Warehouse and Factory: Floor Slab Settlement Correction and Void Filling Work

Due to ground subsidence, there is sinking and sagging in the concrete floor! The items remain as they are, and the concrete floor will be repaired in a short time.

We would like to introduce a case of "floor sinking correction and void filling work" carried out at a warehouse and factory located in Hokkaido. Due to the effects of ground subsidence, there were signs of sinking and sagging in the floor, and we received a request for correction from the company. Before the work, the racks used for storing goods, which had become tilted due to floor sinking, were adjusted in height using spacers, but after the work, they became flat. [Case Overview] ■ Construction Area: 334m2 ■ Maximum Sinking Amount: 105mm ■ Construction Period: 3 days ■ Area: Sapporo City, Hokkaido *For more details, please refer to the PDF document or feel free to contact us.

  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Large Pachinko Parlor: Earthquake Recovery Work / Slab Floor Settlement Correction Work

Settlement due to compaction: Significant sinking of the floor inside the store due to the impact of the Great East Japan Earthquake! We will introduce our response case.

We would like to introduce a case of "earthquake recovery work" and "floor subsidence correction work" carried out at a large pachinko parlor located in Fukushima Prefecture. In this case, the floor inside the store significantly subsided due to consolidation settlement and the impact of the Great East Japan Earthquake. The tilt of the floor caused discomfort while walking inside the store. An up-con method that can be corrected during nighttime when the store is closed was adopted, and our company carried out the subsidence correction work. 【Case Overview】 ■ Construction Area: Approximately 700m2 ■ Maximum Subsidence: 161mm ■ Area: Fukushima Prefecture ■ Construction Period: Continuous 4 nights *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] Supermarket: Subfloor Settlement Correction Work (Chiba Prefecture)

Due to the impact of the Great East Japan Earthquake, the floor inside the store sank! A case where repairs were made during the night while the store was closed.

Here is a case study of "subfloor sinking correction work" conducted at a large supermarket in Chiba Prefecture. Due to the impact of the Great East Japan Earthquake, the floor inside the store sank significantly. The Upcon method, which can be corrected during the night while the store is closed, was adopted, and our company carried out the correction. Since the store mainly handles fresh food products, during the construction, we not only used plastic sheets for protection around the injection gun but also enclosed the injectors to prevent resin dispersion while working. [Case Overview] ■ Construction Area: Approximately 2,000 m² ■ Maximum Sinking Amount: 99 mm ■ Area: Chiba Prefecture ■ Construction Period: Continuous 9 nights * To expedite the construction period, two construction plant vehicles were used (2011). * For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] Repairing the gaps in the floors and walls of a large shopping center.

A significant subsidence of the floor due to weak ground! Introducing a case where repairs were made at night during the business closure.

Here is a case study of "floor sinking correction" conducted at a large shopping center in Nara Prefecture. Due to weak ground, the floor sank significantly. As a result of the floor sinking, gaps were observed in various places, such as between the floor and the walls and between the walls and the ceiling. An up-con method that can be corrected during nighttime while the business is closed was adopted, and our company carried out the correction. 【Case Overview】 ■ Construction Area: Approximately 3,240m2 (Backyard 405m2, Inside Store 2,835m2) ■ Maximum Sinking Amount: 94mm ■ Area: Nara Prefecture ■ Construction Period: 25 nights ※ Supported by 2 construction plant vehicles *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Apartment: Correction of Sunken Floor in Entrance Hall / Filling of Underfloor Gaps and Voids

Resolve issues such as 'gaps between the wall and ceiling' in just one day with the Upcon construction method!

We would like to introduce a case of "subfloor sinking correction work" and "subfloor void filling work" carried out in a condominium located in Niigata Prefecture. In the RC apartment building (1st floor) we are introducing this time, due to floor sinking, there were issues not only with "floor tilting" but also with "gaps occurring between the walls and ceiling" and "doors not closing." After completing the subfloor sinking correction work and the subfloor void (cavity) work, the gaps between the walls and ceiling were eliminated, and the misaligned tile joints were leveled. Additionally, the doors that had been unable to close due to frame distortion from sinking were now able to close properly. 【Case Overview】 ■ Construction Area: 69m2 ■ Maximum Sinking Amount: 36mm ■ Maximum Void Amount: 190mm ■ Area: Niigata Prefecture ■ Construction Period: 1 day *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Middle School (Gymnasium Floor): Settlement Correction and Void Filling Work

Due to the impact of the earthquake, the gymnasium floor has significantly sunk in a bowl shape! A case where the Upcon method was used to solve the problem.

We would like to introduce a case of "settlement correction and void filling work" carried out on the gymnasium floor of a junior high school in Fukushima Prefecture. Due to the effects of an earthquake, the floor had significantly sunk in a bowl shape from the outer edges towards the center, causing issues with the use of the gymnasium. The area that had sunk by a maximum of 108mm was corrected to within the planned value of -15mm, and it was confirmed using a CCD camera that the polyurethane resin was filled without any gaps, completing the work. [Case Overview] ■ Construction Area: 1,036m2 ■ Construction Period: 8 days ■ Maximum Settlement: 108mm ■ Area: Fukushima Prefecture *For more detailed information about the case, please refer to the related links. For further details, please check the PDF materials or feel free to contact us.

  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] Elementary School: Floor Slab Settlement Correction Work

Utilizing spring break for quick subsidence correction! The cycle from construction to restoration is short.

Here is an example of "settlement correction" performed at an elementary school in Miyagi Prefecture. Due to floor settlement, gaps occurred between the classroom walls and ceiling, causing the classroom door to tilt and hindering the opening and closing of the lock. The overall floor level of the classroom and hallway was corrected from a maximum settlement of 69mm to within -18mm, and the gaps that had formed between the walls and ceiling before the work were also improved. 【Case Summary】 ■ Construction Area: 331m2 ■ Maximum Settlement: 69mm ■ Area: Tagajo City, Miyagi Prefecture / Elementary School ■ Construction Period: 4 days *For more detailed information about the case, please refer to the related link. For further details, please check the PDF document or feel free to contact us.

  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

TerraTech method for correcting tilts, subsidence, and level differences in floors and buildings: Case study collection giveaway.

We solve problems such as ground improvement and ground strengthening under buildings, mainly through settlement correction and void filling work using the Terra Tech method! We have surpassed 4,500 construction achievements.

●What is the Teratech Method… It is a patented method that involves injecting rigid polyurethane foam "Teratech resin" under concrete floors to fill voids and level sunken floors using its expansion force. Since it does not require breaking the floor, operations can continue without moving shelves or machinery! ▼Various issues we have resolved 【Tilt】 - Struggling with uneven factory floors. Want to make the concrete floor flat. - The warehouse floor has sunk in a bowl shape, causing vibrations during forklift operation. - The area where machines are installed has sunk, causing tilting of the machines. 【Subsidence】 - Found tilting in the foundation, making repairs impossible. - The concrete floor of the school gymnasium has sunk, except for the underground beams. - There are depressions on the warehouse floor, raising concerns about product storage and worker safety. 【Step Differences】 - There are step differences in the floor, causing product defects such as loads falling. - There is a step at the entrance of the refrigerated warehouse, making it difficult for forklifts to pass. 【Hollows and Gaps】 - The vibrations from the machines have worsened. I would like to check for any voids. - Cracks have appeared under the floor. We are struggling with corrosion of stored items and pest infestations. - Due to flooding, the soil under the concrete has been washed away, creating voids.

  • 画像1.png
  • 画像2.png
  • 画像3.png
  • 画像4.png
  • 画像5.png
  • 2.JPG
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Example] Warehouse and Factory in Sapporo City, Hokkaido

We would like to introduce a case where we made corrections in a short time without interrupting the customer's operations!

This is a case study of floor sinking correction work and void filling work conducted at a warehouse and factory located in Sapporo City, Hokkaido. Due to floor sinking, the racks used for storing goods had become tilted. As a temporary measure, spacers were used under the racks to adjust their height and level them. The sinking correction work was carried out in a limited space, and within a few hours, the floor was made flat. Additionally, sinking correction work was performed in the office without interrupting the customer's operations. [Case Study] ■ Total construction area: Approximately 334 m² ■ Maximum sinking amount: 105 mm ■ Construction period: 3 days *For more details, please refer to the PDF document or feel free to contact us.